LED high mast lighting is very energy efficient and has a long service life. The LED technology continues to develop, and enables a more efficient, long lasting, and cost-worthy light source. The larger the area you want to light up, the higher your lights will need to be mounted on. If you need to illuminate large areas like airports, car parks or major roads, you'll need to use high mast lighting.
Images for LED high mast lighting application
|
1、LED high mast lighting distribution
With LED high mast lighting, it's not just about how much light you get; it's about where it goes with traditional lights. Sources reflect as we used to put the light where IT was needed. Now With LEDs we can use lenses which give us even more precision to put the light just where IT's required and avoid light pollution
With LED high mast lighting, you often have neighbors in an area surrounding that depot or the yard. So you also have to make sure that you have minimal tilt requirements. And that's usually achieved through optic lenses.
You may have cars, trucks, or even planes moving about beneath your lights. You don't want to serve them with glare. Similarly, if there are houses nearby, you don't want to disturb them either.
Images for LED high mast lighting distribution
|
Old fashioned sun or sox lamps gave an orangey glow which made it difficult to recognize colors properly. Nowadays with HID and LED lights the lights white, which means you get much better color rendering
When you've got light mounted up this high, you really don't want to have to change a lamp if you can possibly avoid it. So make sure you choose a product that's going to last you a long time and make sure you quiz the manufacturer on how long its really going to last. Are you getting a warranty with the product and what does the lifetime of the product really mean if they say fifty thousand dollars? Is it going to die after fifty thousand hours? Or has it just lost some of its output? Ask these questions of the manufacturer and if you're not happy with the answers pick another manufacturer
You can save loads of energy by turning your lights off automatically or dimming them in response to time or movement all levels of light.
We think about with LED opens up a whole new world have been out a dim control LED and look at different ways of being more flexible within a working environment. Gone other days when it took ten or fifteen minutes for light slightly used to warm up and we no longer have the problem of warm restrike when you had to wait a long time after turning lights off before you could put them back on again with LEDs you can switch them on and off as often as you like.
Janus Intelligent Lighting Control System for LED high mast control
|
Retrofitting new LED lights to existing columns is fairly straightforward these days, which makes upgrading to new technology that be easier. And with LED lights you can spread the weight of the loom and as on your columns more easily because you can direct the light more carefully in the direction you want it to go.
6、LED high mast lighting layout calculation
The following information is required to complete a high mast lighting layout calculation and determine what Bill of Material and other equipment is needed to complete a floodlighting installation according to the indicated requirements
Location of Project
This information is needed to analyze and define the applicable voltage and current feeds that will be present for the project along with organizing the lighting calculations
Input Voltage
Used to validate the product models required for the project. Main input voltage supported is 120-277V at 50/60 Hz.
AutoCAD .dwg or .dxf files of the area to be lighted
Drawing should show a clear definition of the areas that have to be illuminated (either shown on the drawing or provide dimensions of the area to light with a clear reference point or otherwise defining the aircraft stand type according to ICAO).
Illumination Standards
This information will be used in the lighting calculations to determine equipment required and validate pole/mast height and locations
Lux Level and Uniformity standards provide guidance on specific illumination requirements. If compliance with a standard is required, indicate the standard (ICAO, FAA, IES Military etc.).
Use of the illuminated area affects the lighting calculations and material required. Aircraft stands require higher illumination standards then general operations areas. Indicate the use in the table.
High mast lighting Pole / Mast design
Retrofitting existing installations: Indicate on the provided drawings the exact position of the poles. Also required is the height of the existing poles and whether there position and heights are already defined or can they be changed. If it can be changed, define the new location and pole height options.
New installations: Indicate on the provided drawings the exact position of the new poles. Also required is the height and type of poles and whether there position and heights are already defined or can it be changed. If it can be changed, define the new location and pole height options.
YAHAM Lighting Compact S LED High Mast Light
7、high mast lighting specifications
LED high mast light is used in different areas and their specifications will be different. Yaham Lighting, the professional LED high mast light manufacturer, offers professional high mast lighting fixtures suits most applications. Please found the general information as follows:
Compact S LED high mast light Specification
|
Lumiway 3 LED high mast light Specification
|
400W/600W/800W/1200W available
High Mast Light Efficacy up to 140lm/W
Luminaire lumens up to 168,000lm
CCT: 4500~5500K(2500~5500K optional)
CRI: Ra75(Ra85 optional)
Beam angle: 30°(60°, 19° optional)
Rating: IP 65, IK08
5 years warranty
LED lifespan > 100,000 hours( TM-21 L70 )
Operating temp -40~+50℃
Electrical: 100-277Vac,47/63Hz, PF≥0.95
|
300W/400W/600W/900W available
High Mast Light Efficacy up to 120lm/W
Luminaire lumens up to 108,000lm
Beam angle: 60°×90° (30°optional)
Rating: IP 65, IK08
5 years warranty
LED lifespan > 100,000 hours( TM-21 L70 )
Operating temp: -40~+50℃
Electrical: 100-277Vac,50/60Hz, PF≥0.95
|
Others
|
Others
|
Power Efficiency
≥93%
Working Temperature (Environment)
-40℃~+45℃
|
Power Efficiency
>93%
Working Temperature (Environment)
-40℃~+55℃
|